PRICES include / exclude VAT
Homepage>CSN EN 14902 - Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter
Sponsored link
Released: 2005
CSN EN 14902 - Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter

CSN EN 14902

Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter

CURRENCY
LANGUAGE
English
French
Number of Standard:CSN EN 14902
Category:835621
Released:2005
DESCRIPTION

EN 14902


EN 14902 Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter - This European Standard specifies a method for the determination of particulate lead (Pb), cadmium (Cd), arsenic (As) and nickel (Ni) in ambient air that can be used in the framework of the European Council Directive on Ambient Air Quality Assessment and Management [1] and the 1st [2] and 4th [3] Daughter Directives. Performance requirements with which the method has to comply are specified in this European Standard. The performance characteristics of the method were determined in comparative field validation tests carried out at four European locations (see [4]). This European Standard specifies a method for sampling of Pb, Cd, As and Ni as part of the PM10 aerosol, microwave digestion of the samples and analysis by graphite furnace atomic absorption spectrometry or by inductively coupled plasma (quadrupole) mass spectrometry. This European Standard is applicable for the measurement of Pb, Cd, As and Ni as part of the PM10 aerosol fraction in the concentration ranges listed in Table 1. Table 1 - Working ranges of the method in ng/m3 From To Pb 1 4 000 Cd 0,1 50 As 0,5 350 Ni 2 100 The actual lower limits of the working ranges depend upon the variability of the laboratory filter blank (5.3.1). The lower limits of the working ranges given in Table 1 are expected values based upon performance achieved in the field validation tests. Similarly the upper limits of the working ranges have been set arbitrarily based upon the maximum daily values measured during the field validation tests. The method can be applied to higher concentrations provided the PM10 collection characteristics of the sampler are not compromised.

Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.